Tone Detection Parameters
The signal tone detection parameters are described in the table below.
Tone Detection Parameters
Parameter |
Description |
||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
dtmf-detector-enable [DTMFDetectorEnable] |
Enables the detection of DTMF signaling.
|
||||||||||||||||||
mfr1-detector-enable [MFR1DetectorEnable] |
Enables the detection of MF-R1 signaling.
|
||||||||||||||||||
mf-transport-type [MFTransportType] |
Defines the method for sending MF digits over the network to the remote side.
|
||||||||||||||||||
user-defined-tones-detector-enable [UserDefinedToneDetectorEnable] |
Enables the detection of User Defined Tones signaling, applicable for Special Information Tone (SIT) detection.
|
||||||||||||||||||
sit-detector-enable [SITDetectorEnable] |
Enables SIT detection according to the ITU-T recommendation E.180/Q.35.
To disconnect IP-to-Tel calls when a SIT tone is detected, configure the following parameters:
Note:
|
||||||||||||||||||
udt-detector-frequency-deviation [UDTDetectorFrequencyDeviation] |
Defines the deviation (in Hz) allowed for the detection of each signal frequency. The valid range is 1 to 50. The default is 50. Note: For the parameter to take effect, a device restart is required. |
||||||||||||||||||
cpt-detector-frequency-deviation [CPTDetectorFrequencyDeviation] |
Defines the deviation (in Hz) allowed for the detection of each CPT signal frequency. The valid range is 1 to 30. The default is 10. Note: For the parameter to take effect, a device restart is required. |